polydetector plus, micropolymer, AEC HRP Red, Horseradish Peroxidase immunohistochemistry Detection System ihc

IHC of PolyDetctor Plus AEC HRP Red staining bcl-6 on FFPE Tonsil Tissue

polydetector plus, micropolymer, AEC HRP Red, Horseradish Peroxidase immunohistochemistry Detection System ihc

ICH of PolyDetctor Plus AEC HRP Red staining Ki-67 on FFPE Melanoma Tissue

polydetector plus, micropolymer, AEC HRP Red, Horseradish Peroxidase immunohistochemistry Detection System ihc

IHC of PolyDetctor Plus AEC HRP Red staining CK10 on FFPE LSIL Cervix Tissue
Specification Sheets
Safety Data Sheet
Intended UseFor In Vitro Diagnostic Use
Summary and Explanation

The Bio SB PolyDetector Plus AEC HRP Red Immunohistochemistry (IHC) detection system from Bio SB, is a highly sensitive 2-step, non-Biotin, Fab micropolymer detection system that allows for the demonstration of antigens in formalin-fixed paraffin-embedded tissues, cryostat sections, blood smears, cytosmears, and cell preparations. The PolyDetector Plus technology was developed and is manufactured with a proprietary micropolymer backbone conjugated to anti-mouse and anti-rabbit Fab Ig’s, plus high quality HRP or AP enzymes. The elimination of the anti-mouse and anti-rabbit immunoglobulin Fc region reduces non-specific reactions. The PolyDetector Plus kit incorporates an Immunoglobulin link and a Fab Micropolymer label.

The PolyDetector Plus is a universal IHC detection system which is optimized for use with Bio SB mouse or rabbit primary antibodies; however, these universal kits could be optimized to work with prediluted and concentrated antibodies from other vendors. The increased sensitivity of this detection system allows for rapid staining procedures without compromising stain quality. This multiple component Fab Micropolymer delivers a highly sensitive and specific signal in a shorter time-frame than the PolyDetector.

PresentationThe Mouse/Rabbit PolyDetector Plus AEC HRP Red Detection System contains a peroxidase blocker, an anti-mouse/rabbit link, a Fab HRP label, and an AEC ready-to-use substrate chromogen. All components are buffered with stabilizers and an anti-microbial agent.
Availability
CAT.#VOL
BSB 0258S5.0 ml
BSB 025815.0 ml
BSB 026050.0 ml
BSB 0262100.0 ml
BSB 0264200.0 ml
BSB 02661000.0 ml
Synonyms: polydetector plus, polydetector +, poly plus, poly +, poly-detector plus, ihc detection, immunohistochemistry detection system, ihc detection system, ac, aec red, aec immunohistochemistry, non-biotin ihc,